Description
Cisco CBS350-12XS Network Switch Kenya
The Cisco CBS350-12XS Kenya is a 12-Port SFP+ 10G Managed Network Switch from Cisco. This managed rackmount switch features ten 10G SFP+ ports and two 10G SFP+/RJ45 combo ports that connect to a variety of high-speed wired devices such as computers, network attached storage, and more. Its extensive Layer 2 and Layer 3 features include secure connections, clear communications, and link aggregation to create up to eight groups. Its 240 Gb/s switching capacity and 178.56 Mpps forwarding rate help to ensure smooth and reliable data transfers. Use the Cisco Business Dashboard portal and mobile app to configure and monitor the Cisco CBS350-12XS and its connected devices. The four fan design helps to maintain optimal temperatures while the switch operates quietly in the background.
Cisco CBS350-12XS Kenya is a portfolio of affordable wireless access points, switches and routers designed and built for Small Business. Managed through Cisco Business Dashboard and mobile app, the Cisco CBS350-12XS Kenya switch provides a simple and reliable experience. Cisco Business Dashboard simplifies traditional challenges in deploying and managing business networks by automating the deployment, monitoring and lifecycle management of the network. The Cisco CBS350-12XS Kenya part of the Cisco Business line of network solutions, is a portfolio of affordable managed switches that provides a critical building block for any small office network. Intuitive dashboard simplifies network setup, and advanced features accelerate digital transformation, while pervasive security protects business critical transactions. The Cisco CBS350-12XS Kenya switch provides the ideal combination of affordability and capabilities for small office and helps you create a more efficient, better-connected workforce.
Features
Secure office connectivity
The Cisco CBS350-12XS Kenya can simply and securely connect employees working in small offices with each other and with all of the servers, printers, and other networking devices they use. High performance and reliable connectivity help speed file transfers and data processing, improve network uptime, and keep your employees connected and productive.
Unified communications
As a managed network solution, Cisco CBS350-12XS Kenya provides the performance and advanced traffic-handling intelligence you need to deliver all communications and data over a single network. Cisco offers a complete portfolio of IP telephony and other unified communications products designed for businesses.
Highly secure guest connectivity
Cisco CBS350-12XS Kenya allow extension of highly secure network connectivity to guests in a variety of settings, such as a hotel, an office waiting room, or any other area open to nonemployee users. Using powerful but easy-to-configure security and traffic segmentation capabilities, you can isolate your vital business traffic from guest services and keep guests’ network sessions private from each other.
Simple Management and Deployment
Cisco CBS350-12XS Kenya is designed to be easy to use and manage by commercial customers or the partners that serve them, including the following features :
- Cisco Business Dashboard is designed to manage Cisco Business switches, routers, and wireless access points. Cisco Business Dashboard simplifies traditional challenges in deploying and managing business networks while automating the deployment, monitoring, and lifecycle management of the network. Cisco Business 350 Series switches support embedded probe for Cisco Business Dashboard, eliminating the need to set up a separate hardware or virtual machine on site.
- The Cisco Network Plug and Play solution provides a simple, secure, unified, and integrated offering to ease new device rollouts or for provisioning updates to an existing network. The solution provides a unified approach to provision Cisco routers, switches, and wireless devices with a near-zero-touch deployment experience.
- The intuitive user interfaces reduce the time required to deploy, troubleshoot, and manage the network and allow you to support sophisticated capabilities without increasing IT head count.
- The switches also support Text view, a full Command-Line Interface (CLI) option for partners that prefer it.
- Support for Simple Network Management Protocol (SNMP) allows you to set up and manage your switches and other Cisco devices remotely from a network management station, improving IT workflow and mass configurations.
High Reliability and Resiliency
Cisco CBS350-12XS Kenya switch supports dual images, allowing you to perform software upgrades without having to take the network offline or worry about the network going down during the upgrade.
Strong Security
Cisco CBS350-12XS Kenya Switch provides the advanced security features you need to protect your business data and keep unauthorized users off the network :
- Support for advanced network security applications such as IEEE 802.1X and port security tightly limits access to specific segments of your network. Web-based authentication provides a consistent interface to authenticate all types of host devices and operating systems, without the complexity of deploying IEEE 802.1X clients on each endpoint.
- Advanced defense mechanisms, including dynamic Address Resolution Protocol (ARP) inspection, IP Source Guard, and Dynamic Host Configuration Protocol (DHCP) snooping, detect and block deliberate network attacks. Combinations of these protocols are also referred to as IP-MAC port binding (IPMB).
- IPv6 First Hop Security extends the advanced threat protection to IPv6. This comprehensive security suite includes ND inspection, RA guard, DHCPv6 guard, and neighbor binding integrity check, providing unparalleled protection against a vast range of address spoofing and man-in-the-middle attacks on IPv6 networks.
Power over Ethernet
Cisco Business 350 Series Switches are available with up to 48 Power over Ethernet (PoE) ports. This capability simplifies advanced technology deployments such as IP telephony, wireless, and IP surveillance by allowing you to connect and power network endpoints over a single Ethernet cable. With no need to install separate power supplies for IP phones or wireless access points, you can take advantage of advanced communications technologies more quickly and at a lower cost. Models support 802.3af PoE and 802.3at PoE+. 60W PoE is also supported on select switches to power high-performance wireless access points and Internet of Things (IoT) devices.
IPv6 Support
As the IP address scheme evolves to accommodate a growing number of network devices, Cisco CBS350-12XS Kenya can support the transition to the next generation of networking. Cisco CBS350-12XS Kenya continue to support previous-generation IPv4, allowing you to evolve to the new IPv6 standard at your own pace and helping ensure that your current network will continue to support your business applications in the future. Cisco Business 350 Series Switches have successfully completed rigorous IPv6 testing and have received the USGv6 and IPv6 Gold certification.
Advanced Layer 3 Traffic Management
Cisco CBS350-12XS Kenya enables a more advanced set of traffic management capabilities to help growing businesses organize their networks more effectively and efficiently. For example, the switches provide dynamic Layer 3 routing, allowing you to segment your network into workgroups and communicate across VLANs without degrading application performance. With these capabilities, you can boost the efficiency of your network by offloading internal traffic-handling tasks from your router and allowing it to manage primarily external traffic and security.
True stacking
Cisco CBS350-12XS Kenya provides true stacking capability, allowing you to configure, manage, and troubleshoot all switches in a stack as a single unit with a single IP address.
A true stack delivers a unified data and control plane, in addition to management plane, providing flexibility, scalability, and ease of use because the stack of units operates as a single entity constituting all the ports of the stack members. This capability can radically reduce complexity in a growing network environment while improving the resiliency and availability of network applications. True stacking also provides other cost savings and administrative benefits through features such as cross-stack QoS, VLANs, LAGs, and port mirroring, which clustered switches cannot support.
Compact Design
The sleek and compact design for Cisco CBS350-12XS Kenya switch provides additional deployment flexibility, including outside wiring closet installation such as retail stores, open plan offices, and classrooms without disturbing the environment.
Power Efficiency
The Cisco CBS350-12XS Kenya integrates a variety of power-saving features across all models, providing the industry’s most extensive energy-efficient switching portfolio. This switch is designed to conserve energy by optimizing power use, which helps protects the environment and reduce your energy costs. They provide an eco-friendly network solution without compromising performance. Cisco Business 350 Series Switches feature :
- Cisco CBS350-12XS Kenya supports for the Energy Efficient Ethernet (IEEE 802.3az) standard, which reduces energy consumption by monitoring the amount of traffic on an active link and putting the link into a sleep state during quiet periods
- Automatic power shutoff on ports when a link is down
- Embedded intelligence to adjust signal strength based on the length of the connecting cable
- Cisco CBS350-12XS Kenya has Fanless design which reduces power consumption, increases reliability, and provides quieter operation
Peace of Mind and Investment Protection
Cisco Business 350 Series Switches offer the reliable performance and peace of mind you expect from a Cisco switch. A solution that has been rigorously tested to help ensure optimal network uptime to ensure business continuity. Complementary one-year access to our Small Business Support Center for ongoing support. Limited lifetime warranty with Next-Business-Day (NBD) advance replacement (where available) keeps your business running smoothly.
Specifications
Switching capacity and forwarding rate | Model | Capacity in millions of packets per second (64-byte packets) | Switching capacity in gigabits per second | |
CBS350-8XT | 119.05 mpps | 160.0 Gbps | ||
CBS350-12XS | 178.56 mpps | 240.0 Gbps | ||
CBS350-12XT | 178.56 mpps | 240.0 Gbps | ||
CBS350-16XTS | 238.08 mpps | 320.0 Gbps | ||
CBS350-24XS | 240.00 mpps | 480.0 Gbps | ||
CBS350-24XT | 240.00 mpps | 480.0 Gbps | ||
CBS350-24XTS | 240.00 mpps | 480.0 Gbps | ||
CBS350-48XT-4X | 755.81 mpps | 1,040.0 Gbps | ||
Layer 2 switching | ||||
Spanning Tree Protocol (STP) |
|
|||
Port grouping/link aggregation |
|
|||
VLAN |
|
|||
Voice VLAN | Voice traffic is automatically assigned to a voice-specific VLAN and treated with appropriate levels of QoS. Auto voice capabilities deliver network wide zero-touch deployment of voice endpoints and call control devices | |||
Multicast TV VLAN | Multicast TV VLAN allows the single multicast VLAN to be shared in the network while subscribers remain in separate VLANs. This feature is also known as Multicast VLAN Registration (MVR) | |||
VLAN Translation | Support for VLAN One-to-One Mapping. In VLAN One-to-One Mapping, on an edge interface customer VLANs (C-VLANs) are mapped to service provider VLANs (S-VLANs) and the original C-VLAN tags are replaced by the specified S-VLAN | |||
Q-in-Q | VLANs transparently cross a service provider network while isolating traffic among customers | |||
Selective Q-in-Q |
|
|||
Generic VLAN Registration Protocol (GVRP) and Generic Attribute Registration Protocol (GARP) | Generic VLAN Registration Protocol (GVRP) and Generic Attribute Registration Protocol (GARP) enable automatic propagation and configuration of VLANs in a bridged domain | |||
Unidirectional Link Detection (UDLD) | UDLD monitors physical connection to detect unidirectional links caused by incorrect wiring or cable/port faults to prevent forwarding loops and black holing of traffic in switched networks | |||
Dynamic Host Configuration Protocol (DHCP) Relay at Layer 2 | Relay of DHCP traffic to DHCP server in different VLAN; works with DHCP Option 82 | |||
IGMP (versions 1, 2, and 3) snooping | IGMP limits bandwidth-intensive multicast traffic to only the requesters; supports 2K multicast groups (source-specific multicasting is also supported) | |||
IGMP querier | IGMP querier is used to support a Layer 2 multicast domain of snooping switches in the absence of a multicast router | |||
HOL blocking | Head-of-Line (HOL) blocking prevention | |||
Loopback detection | Loopback detection provides protection against loops by transmitting loop protocol packets out of ports on which loop protection has been enabled. It operates independently of STP | |||
Layer 3 routing | ||||
IPv4 routing |
|
|||
IPv6 routing | Wire-speed routing of IPv6 packets | |||
Layer 3 interface | Configuration of Layer 3 interface on physical port, Link Aggregation (LAG), VLAN interface, or loopback interface | |||
Classless Interdomain Routing (CIDR) | Support for classless interdomain routing | |||
RIP v2 | Support for Routing Information Protocol version 2 for dynamic routing | |||
Policy-Based Routing (PBR) | Flexible routing control to direct packets to different next hop based on IPv4 or IPv6 Access Control List (ACL) | |||
DHCP Server |
|
|||
DHCP relay at Layer 3 | Relay of DHCP traffic across IP domains | |||
User Datagram Protocol (UDP) relay | Relay of broadcast information across Layer 3 domains for application discovery or relaying of Bootstrap Protocol (BOOTP)/DHCP packets | |||
Stacking | ||||
Hardware stacking | Up to 4 units in a stack. Up to 192 ports managed as a single system with hardware failover | |||
High availability | Fast stack failover delivers minimal traffic loss. Support link aggregation across multiple units in a stack | |||
Plug-and-play stacking configuration/management |
|
|||
High-speed stack interconnects | Cost-effective high-speed 10G fiber interfaces | |||
Security | ||||
Secure Sockets Layer (SSL) | SSL support : Encrypts all HTTPS traffic, allowing highly secure access to the browser-based management GUI in the switch | |||
Secure Shell (SSH) Protocol | SSH is a secure replacement for Telnet traffic. Secure Copy Protocol (SCP) also uses SSH. SSH v1 and v2 are supported | |||
IEEE 802.1X (authenticator role) | 802.1X : Remote Authentication Dial-In User Service (RADIUS) authentication and accounting, MD5 hash; guest VLAN; unauthenticated VLAN, single/multiple host mode and single/multiple sessions Supports time-based 802.1X; dynamic VLAN assignment |
|||
Web-based authentication | Web-based authentication provides network admission control through web browser to any host devices and operating systems | |||
STP Bridge Protocol Data Unit (BPDU) Guard | A security mechanism to protect the network from invalid configurations. A port enabled for BPDU Guard is shut down if a BPDU message is received on that port. This avoids accidental topology loops | |||
STP Root Guard | This prevents edge devices not in the network administrator’s control from becoming Spanning Tree Protocol root nodes | |||
STP loopback guard | Provides additional protection against Layer 2 forwarding loops (STP loops) | |||
DHCP snooping | Filters out DHCP messages with unregistered IP addresses and/or from unexpected or untrusted interfaces. This prevents rogue devices from behaving as DHCP Servers. | |||
IP Source Guard (IPSG) | When IP Source Guard is enabled at a port, the switch filters out IP packets received from the port if the source IP addresses of the packets have not been statically configured or dynamically learned from DHCP snooping. This prevents IP address spoofing. | |||
Dynamic ARP Inspection (DAI) | The switch discards ARP packets from a port if there are no static or dynamic IP/MAC bindings or if there is a discrepancy between the source or destination addresses in the ARP packet. This prevents man-in-the-middle attacks. | |||
IP/MAC/Port Binding (IPMB) | The preceding features (DHCP Snooping, IP Source Guard, and Dynamic ARP Inspection) work together to prevent DOS attacks in the network, thereby increasing network availability | |||
Secure Core Technology (SCT) | Makes sure that the switch will receive and process management and protocol traffic no matter how much traffic is received | |||
Secure Sensitive Data (SSD) | A mechanism to manage sensitive data (such as passwords, keys, and so on) securely on the switch, populating this data to other devices, and secure autoconfig. Access to view the sensitive data as plaintext or encrypted is provided according to the user-configured access level and the access method of the user. | |||
Trustworthy systems |
|
|||
Private VLAN Multiple user privilege levels in CLI | Private VLAN provides security and isolation between switch ports, which helps ensure that users cannot snoop on other users’ traffic; supports multiple uplinks | |||
Layer 2 isolation Private VLAN Edge (PVE) with community VLAN | PVE (also known as protected ports) provides Layer 2 isolation between devices in the same VLAN, supports multiple uplinks | |||
Port security | Ability to lock source MAC addresses to ports and limits the number of learned MAC addresses | |||
RADIUS/TACACS+ | Supports RADIUS and TACACS authentication. Switch functions as a client | |||
RADIUS accounting | The RADIUS accounting functions allow data to be sent at the start and end of services, indicating the amount of resources (such as time, packets, bytes, and so on) used during the session | |||
Storm control | Broadcast, multicast, and unknown unicast | |||
DoS prevention | Denial-of-Service (DOS) attack prevention | |||
Multiple user privilege levels in CLI | Level 1, 7, and 15 privilege levels | |||
ACLs |
|
|||
Quality of service | ||||
Priority levels | 8 hardware queues | |||
Scheduling | Strict priority and Weighted Round-Robin (WRR) | |||
Class of service |
|
|||
Rate limiting | Ingress policer; egress shaping and rate control; per VLAN, per port, and flow based; 2R3C policing | |||
Congestion avoidance | A TCP congestion avoidance algorithm is required to minimize and prevent global TCP loss synchronization | |||
iSCSI traffic optimization | A mechanism for giving priority to iSCSI traffic over other types of traffic | |||
Standards | ||||
Standards | IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, IEEE 802.3ad Link Aggregation Control Protocol, IEEE 802.3z Gigabit Ethernet, IEEE 802.3ae 10 Gbit/s Ethernet over fiber for LAN, IEEE 802.3an 10GBase-T 10 Gbit/s Ethernet over copper twisted pair cable, IEEE 802.3x Flow Control, IEEE 802.1D (STP, GARP, and GVRP), IEEE 802.1Q/p VLAN, IEEE 802.1w Rapid STP, IEEE 802.1s Multiple STP, IEEE 802.1X Port Access Authentication, IEEE 802.3af, IEEE 802.3at, IEEE 802.1AB Link Layer Discovery Protocol, IEEE 802.3az Energy Efficient Ethernet, RFC 768, RFC 783, RFC 791, RFC 792, RFC 793, RFC 813, RFC 826, RFC 879, RFC 896, RFC 854, RFC 855, RFC 856, RFC 858, RFC 894, RFC 919, RFC 920, RFC 922, RFC 950, RFC 951, RFC 1042, RFC 1071, RFC 1123, RFC 1141, RFC 1155, RFC 1157, RFC 1213, RFC 1215, RFC 1286, RFC 1350, RFC 1442, RFC 1451, RFC 1493, RFC 1533, RFC 1541, RFC 1542, RFC 1573, RFC 1624, RFC 1643, RFC 1700, RFC 1757, RFC 1867, RFC 1907, RFC 2011, RFC 2012, RFC 2013, RFC 2030, RFC 2131, RFC 2132, RFC 2233, RFC 2576, RFC 2616, RFC 2618, RFC 2665, RFC 2666, RFC 2674, RFC 2737, RFC 2819, RFC 2863, RFC 3164, RFC 3176, RFC 3411, RFC 3412, RFC 3413, RFC 3414, RFC 3415, RFC 3416, RFC 4330 | |||
IPv6 | ||||
IPv6 |
|
|||
IPv6 QoS | Prioritize IPv6 packets in hardware | |||
IPv6 ACL | Drop or rate limit IPv6 packets in hardware | |||
IPv6 First Hop Security |
|
|||
Multicast Listener Discovery (MLD v1/2) snooping | Deliver IPv6 multicast packets only to the required receivers | |||
IPv6 applications | Web/SSL, Telnet server/SSH, ping, traceroute, Simple Network Time Protocol (SNTP), Trivial File Transfer Protocol (TFTP), SNMP, RADIUS, syslog, Domain Name System (DNS) client, Telnet Client, DHCP Client, DHCP Autoconfig, IPv6 DHCP Relay, Terminal Access Controller Access Control System Plus (TACACS+) | |||
IPv6 RFCs supported |
|
|||
Management | ||||
Cisco Business Dashboard | Support for embedded probe for Cisco Business Dashboard running on the switch. Eliminates the need to set up a separate hardware or virtual machine for the Cisco Business Dashboard Probe on site. | |||
Cisco Business mobile app | Mobile app for Cisco Business Switch and Wireless products. Helps to set up a local network in minutes and provide easy management at your fingertips. | |||
Cisco Network Plug and Play (PnP) agent |
|
|||
Web user interface |
|
|||
SNMP | SNMP versions 1, 2c, and 3 with support for traps, and SNMP v3 User-based Security Model (USM) | |||
Standard MIBs |
|
|
||
Private MIBs |
|
|
||
Remote monitoring (RMON) | Embedded RMON software agent supports 4 RMON groups (history, statistics, alarms, and events) for enhanced traffic management, monitoring, and analysis | |||
IPv4 and IPv6 dual stack | Coexistence of both protocol stacks to ease migration | |||
Firmware upgrade |
|
|||
Port mirroring | Traffic on a port can be mirrored to another port for analysis with a network analyzer or RMON probe. Up to 4 source ports can be mirrored to one destination port | |||
VLAN mirroring | Traffic from a VLAN can be mirrored to a port for analysis with a network analyzer or RMON probe. Up to 4 source VLANs can be mirrored to one destination port | |||
Dynamic Host Configuration Protocol (DHCP) (options 12, 66, 67, 129, and 150) | DHCP options facilitate tighter control from a central point (DHCP server), to obtain IP address, auto-configuration (with configuration file download), DHCP Relay, and host name | |||
Secure Copy (SCP) | Securely transfers files to and from the switch | |||
Autoconfiguration with SCP file download | Enables mass deployment with protection of sensitive data | |||
Text-editable configs | Config files can be edited with a text editor and downloaded to another switch, facilitating easier mass deployment | |||
Smartports | Simplified configuration of QoS and security capabilities | |||
Auto Smartports | Automatically applies the intelligence delivered through the Smartports roles to the port based on the devices discovered over Cisco Discovery Protocol or LLDP-MED. This facilitates zero-touch deployments. | |||
Text view Command-Line Interface (CLI) | Scriptable CLI. A full CLI as well as a menu-based CLI is supported. User privilege levels 1, 7, and 15 are supported for the CLI. | |||
Localization | Localization of GUI and documentation into multiple languages | |||
Login banner | Configurable multiple banners for web as well as CLI | |||
Other management | Traceroute; single IP management; HTTP/HTTPS; RADIUS; port mirroring; TFTP upgrade; DHCP client; Simple Network Time Protocol (SNTP); cable diagnostics; Ping; syslog; Telnet client (SSH secure support); automatic time settings from Management Station | |||
Green (Power Efficiency) | ||||
Energy detect | Automatically turns power off on RJ-45 port when detecting link down. Active mode is resumed without loss of any packets when the switch detects the link is up | |||
Cable length detection | Adjusts the signal strength based on the cable length. Reduces the power consumption for shorter cables | |||
EEE compliant (802.3az) | Supports IEEE 802.3az on all copper Gigabit Ethernet ports | |||
Disable port LEDs | LEDs can be manually turned off to save on energy | |||
Time-based port operation | Link up or down based on user-defined schedule (when the port is administratively up) | |||
Time-based PoE | PoE power can be on or off based on user-defined schedule to save energy | |||
General | ||||
Jumbo frames | Frame sizes up to 9K bytes. The default MTU is 2K bytes | |||
MAC table | 16K addresses | |||
Discovery | ||||
Bonjour | The switch advertises itself using the Bonjour protocol | |||
Link Layer Discovery Protocol (LLDP) (802.1ab) with LLDP-MED extensions | Link Layer Discovery Protocol (LLDP) allows the switch to advertise its identification, configuration, and capabilities to neighboring devices that store the data in a MIB. LLDP-MED is an enhancement to LLDP that adds the extensions needed for IP phones | |||
Cisco Discovery Protocol | The switch advertises itself using the Cisco Discovery Protocol. It also learns the connected device and its characteristics using Cisco Discovery Protocol | |||
Power over Ethernet (PoE) | ||||
Power consumption (worst case) | Model | System power consumption | Power consumption (with PoE) | Heat dissipation (BTU/hr) |
CBS350-8XT | 110V=50.3W 220V=50.3W |
N/A | 171.6 | |
CBS350-12XS | 110V=24.3W 220V=25.3W |
N/A | 86.33 | |
CBS350-12XT | 110V=63.9W 220V=64.1W |
N/A | 218.7 | |
CBS350-16XTS | 110V=57W 220V=57.7W |
N/A | 196.88 | |
CBS350-24XS | 110V=38.5W 220V=39.0W |
N/A | 133.1 | |
CBS350-24XT | 110V=124.1W 220V=124.5W |
N/A | 424.8 | |
CBS350-24XTS | 110V=78.4W 220V=80.2W |
N/A | 273.65 | |
CBS350-48XT-4X | 110V=234.4W 220V=229.2W |
N/A | 799.8 | |
Ports | Model name | Total system ports | RJ-45 ports | Combo ports (RJ-45 + SFP) |
CBS350-8XT | 6 x 10G copper + 2 x 10G copper/SFP+ combo + 1 x GE OOB management | 6 x 10G copper | 2 x 10G copper/SFP+ combo | |
CBS350-12XS | 10 x 10G SFP+ + 2 x 10G copper/SFP+ combo + 1 x GE OOB management | 10 x 10G SFP+ | 2 x 10G copper/SFP+ combo | |
CBS350-12XT | 10 x 10G copper + 2 x 10G copper/SFP+ combo + 1 x GE OOB management | 10 x 10G copper | 2 x 10G copper/SFP+ combo | |
CBS350-16XTS | 8 x 10G copper + 8 x 10G SFP+ + 1 x GE OOB management | 8 x 10G copper | 8 x 10G SFP+ | |
CBS350-24XS | 20 x 10G SFP+ + 4 x 10G copper/SFP+ combo + 1 x GE OOB management | 20 x 10G SFP+ | 4 x 10G copper/SFP+ combo | |
CBS350-24XT | 20 x 10G copper + 4 x 10G copper/SFP+ combo + 1 x GE OOB management | 20 x 10G copper | 4 x 10G copper/SFP+ combo | |
CBS350-24XTS | 12 x 10G copper + 12 x 10G SFP+ + 1 x GE OOB management | 12 x 10G copper | 12 x 10G SFP+ | |
CBS350-48XT-4X | 48 x 10G copper + 4 x 10G SFP+ + 1 x GE OOB management | 48 x 10G copper | 4 x 10G SFP+ | |
Console port | Cisco standard RJ45 console port | |||
USB slot | USB Type-A slot on the front panel of the switch for easy file and image management | |||
Buttons | Reset button | |||
Cabling type | Unshielded Twisted Pair (UTP) Category 5e or better for 1000BASE-T | |||
LEDs | System, Link/Act, PoE, Speed | |||
Flash | 256 MB | |||
CPU | 800 MHz ARM | |||
DRAM | 512 MB | |||
Packet buffer | All numbers are aggregate across all ports because the buffers are dynamically shared : | |||
Model name | Packet buffer | |||
CBS350-8XT | 6 MB | |||
CBS350-12XS | 3 MB | |||
CBS350-12XT | 3 MB | |||
CBS350-16XTS | 3 MB | |||
CBS350-24XS | 3 MB | |||
CBS350-24XT | 3 MB | |||
CBS350-24XTS | 3 MB | |||
CBS350-48XT-4X | 10 MB | |||
Supported SFP/SFP+ modules | SKU | Media | Speed | Maximum distance |
MGBSX1 | Multimode fiber | 1000 Mbps | 500 m | |
MGBLH1 | Single-mode fiber | 1000 Mbps | 40 km | |
MGBLX1 | Single-mode fiber | 1000 Mbps | 10 km | |
MGBT1 | UTP cat 5e | 1000 Mbps | 100 m | |
GLC-SX-MMD | Multimode fiber | 1000 Mbps | 550 m | |
GLC-LH-SMD | Single-mode fiber | 1000 Mbps | 10 km | |
GLC-BX-U | Single-mode fiber | 1000 Mbps | 10 km | |
GLC-BX-D | Single-mode fiber | 1000 Mbps | 10 km | |
GLC-TE | UTP cat 5e | 1000 Mbps | 100 m | |
SFP-H10GB-CU1M | Copper coax | 10 Gig | 1 m | |
SFP-H10GB-CU3M | Copper coax | 10 Gig | 3 m | |
SFP-H10GB-CU5M | Copper coax | 10 Gig | 5 m | |
SFP-10G-SR | Multimode fiber | 10 Gig | 26 m – 400 m | |
SFP-10G-LR | Single-mode fiber | 10 Gig | 10 km | |
SFP-10G-SR-S | Multimode fiber | 10 Gig | 26 m – 400 m | |
SFP-10G-LR-S | Single-mode fiber | 10 Gig | 10 km | |
Environmental | ||||
Unit dimensions (W x D x H) |
Model name | Unit dimensions | ||
CBS350-8XT | 440 x 203 x 44 mm (17.3 x 8.0 x 1.73 in) | |||
CBS350-12XS | 440 x 257 x 44 mm (17.3 x 10.12 x 1.73 in) | |||
CBS350-12XT | 440 x 203 x 44 mm (17.3 x 8.0 x 1.73 in) | |||
CBS350-16XTS | 440 x 257 x 44 mm (17.3 x 10.12 x 1.73 in) | |||
CBS350-24XS | 440 x 350 x 44 mm (17.3 x 13.78 x 1.73 in) | |||
CBS350-24XT | 440 x 350 x 44 mm (17.3 x 13.78 x 1.73 in) | |||
CBS350-24XTS | 440 x 350 x 44 mm (17.3 x 13.78 x 1.73 in) | |||
CBS350-48XT-4X | 440 x 450 x 44 mm (17.3 x 17.72 x 1.73 in) | |||
Unit weight | Model name | Unit weight | ||
CBS350-8XT | 2.98 kg (6.57 lb) | |||
CBS350-12XS | 3.42 kg (7.54 lb) | |||
CBS350-12XT | 2.93 kg (6.46 lb) | |||
CBS350-16XTS | 3.79 kg (8.36lb) | |||
CBS350-24XS | 4.4 kg (9.7 lb)) | |||
CBS350-24XT | 5.1 kg (11.2 lb) | |||
CBS350-24XTS | 4.84 kg (10.67 lb) | |||
CBS350-48XT-4X | 7.29 kg (16.1 lb) | |||
Power | 100-240V 50-60 Hz, internal, universal | |||
Certification | UL (UL 60950), CSA (CSA 22.2), CE mark, FCC Part 15 (CFR 47) Class A | |||
Operating temperature | 32° to 122°F (0° to 50°C) | |||
Storage temperature | -13° to 158°F (-25° to 70°C) | |||
Operating humidity | 10% to 90%, relative, non-condensing | |||
Storage humidity | 10% to 90%, relative, non-condensing | |||
Acoustic noise and Mean Time Between Failures (MTBF) | Model name | Fan (number) | Acoustic noise | MTBF at 25°C (hours) |
CBS350-8XT | 2 | 25°C : 40.8 dB | 1,418,411 | |
CBS350-12XS | 4 | 25°C : 45.8 dB | 1,385,554 | |
CBS350-12XT | 2 | 25°C : 40.5 dB | 633,324 | |
CBS350-16XTS | 3 | 25°C : 39.1 dB | 798,504 | |
CBS350-24XS | 4 | 25°C : 43.0 dB | 1,356,179 | |
CBS350-24XT | 4 | 25°C : 41.2 dB | 556,642 | |
CBS350-24XTS | 3 | 25°C : 43.3 dB | 1,372,246 | |
CBS350-48XT-4X | 5 | 25°C : 47.9 dB | 287,135 | |
Warranty | Limited lifetime | |||
Package contents | ||||
|
Â