Description
Ruijie RGS6120-20XS4VS2QXS Network Switch Kenya
Ruijie RGS6120-20XS4VS2QXS Kenya offer high-performance and comprehensive end-to-end QoS, as well as flexible and feature-rich security settings for large-scale network aggregation as well as small and medium-sized network cores, meeting the needs of high-speed, high-security and smart enterprise networks. The Ruijie RGS6120-20XS4VS2QXS Network Switch features next-generation 10G Ethernet switches with high performance and high security newly launched by Ruijie. Adopting advanced hardware architecture design and Ruijie’s new RGOS gen 12th modular operating system, the switches provide faster hardware processing performance and more convenient operating experience. RG-S6120 series provides maximum 32 10G fiber access and supports high-performance 10/25/40G port uplink, which fully meets the user requirements of high-density access and high-performance aggregation.
The Ruijie RGS6120-20XS4VS2QXS Kenya provides hardware support for IPv4/IPv6 dual stack multilayer switching at line speeds, supports IPv4 and IPv6 packet discrimination and processing in hardware, and provides flexible IPv6 network communication solutions according to the IPv6 network requirements for network planning. or maintaining the current state of the network. The Ruijie RGS6120-20XS4VS2QXS Kenya also support a wide range of IPv4 routing protocols, including static routing, RIP, OSPFv2, IS-ISv4, BGP4, etc., allowing users to choose the appropriate protocols for building a network in various environments. The series also supports a wide range of IPv6 routing protocols such as static routing, RIPng, OSPFv3, IS-ISv6, BGP4+, etc.,
Features
- Up to 32 x 10G Base-X Access Ports and 4 25G & 2 40G uplink
- Built-in Advanced Layer 3 Routing Support
- Power and Fan Redundancy Support (hot-swappable)
- Robust High Reliability Hardware Design (Guarantee for 30 Years MTBF)
IPv4/IPv6 Dual-Stack Multilayer Switching
Ruijie RGS6120-20XS4VS2QXS Kenya provides hardware support for IPv4/IPv6 dual-stack multilayer switching at line rates, supports distinction and processing of IPv4 and IPv6 packets by hardware, and provides flexible IPv6 network communication solutions according to the requirements of the IPv6 network for network planning or maintaining the current network status. The switches also support a wide range of IPv4 routing protocols, including static routing, RIP, OSPFv2, IS-ISv4, BGP4, etc., enabling users to select appropriate protocols for network building in different environments. The series also supports an abundant list of IPv6 routing protocols, such as static routing, RIPng, OSPFv3, IS-ISv6, BGP4+, etc., enabling users to select appropriate protocols for upgrading an existing network to IPv6 or building a new IPv6 network.
Virtual Switch Unit (VSU)
The Virtual Switch Unit technology, or VSU in short, enables interconnection of several physical devices via link aggregation by virtualizing them into one logical device. The logical device uses one single IP address, Telnet process, command-line interface (CLI), and enables auto version inspection and configuration for management. From the user perspective, they are only managing one device, but realizing the work efficiency and user experience brought by several devices operating at the same.
Link aggregation can be either 10G ports or dedicated stack cards for user’s investment protection brining various benefits
- Easy management: Administrators can centrally manage all the devices at the same time. It is no longer necessary to configure and manage the switches one by one.
- Simplified typology: The VSU is regarded as one switch in the network. By connection of aggregation link and peripheral network devices, MSTP protocol is unnecessary as there is no Layer 2 loop network. All protocols operate as one switch.
- Millisecond failover: The VSU and peripheral devices are connected via the aggregation link. Upon failure of any device or link, failover to another member link requires only 50 to 200ms.
- Exceptional scalability: The network is hot swappable. Any devices leaving or joining the virtualized network cause zero impact on other devices.
Reliable Design
Ruijie RGS6120-20XS4VS2QXS Kenya adopt multiple-tier hardware fault isolation and protection mechanism, guarantee for 30 Years MTBF. RG-S6120 series switches offers built-in power modules and fan modules redundancy. Both the power modules and the fan modules can be hot swapped without affecting the normal operation of the device. In addition, the Network Switch also support fault detection and alarm for power modules and fan modules and automatically adjust the fan speed according to temperature changes to better adapt to the environment. The devices support front/rear ventilation to improve heat dissipation efficiency and provide multiple reliability protections at the equipment level and link level. Overcurrent protection, overvoltage protection and overheat protection technology are also adopted.
Energy Saving
The Ruijie RGS6120-20XS4VS2QXS Kenya adopt the next-generation hardware architecture, advanced energy-saving circuit design and components to save energy for users and reduce noise pollution. The series adopts the variable-speed axial fans so that the devices can intelligently control the fan speed according to the current temperature to ensure stable operation of the device while reducing power consumption and noise.
Easy Network Maintenance
Ruijie RGS6120-20XS4VS2QXS Network Switch Kenya supports abundant features such as SNMP, RMON, Syslog, logs and configuration backup using USB for routine network diagnosis and maintenance. Administrators can use a wide variety of management and maintenance methods for easier device management and such include command line interface (CLI), web management, Telnet, etc.
Abundant QoS Policies
Ruijie RGS6120-20XS4VS2QXS Kenya offers multilayer traffic classification and flow control for MAC traffic, IP traffic, application traffic, etc. and realizes various traffic policies such as refined bandwidth control and forwarding priority. The series also supports customized QoS features for various applications. The DiffServ-based QoS system supports a complete set of QoS policies covering 802.1P, IP TOS, Layer 2 to 7 filtering, SP, WRR, etc., and realizes the multi-service QoS logic of the entire network system
Specifications
Model | RG-S6120-20XS4VS2QXS | |
Basic specifications | ||
Fixed ports |
|
|
Management ports |
|
|
Switching capacity | 2.56T/23.04T | |
Packet forwarding rate | 570Mpps/1260Mpps | |
Port Buffer | 4MB | |
ARP Table | Up to 16K | |
MAC Address | Up to 32K | |
Routing Table Size (IPv4/IPv6) |
4K/4K | |
ACL Entries | Up to 2500 | |
Product Features | ||
VLAN |
|
|
QinQ | Basic QinQ | |
Link aggregation | LACP (802.3ad) | |
Port mirroring |
|
|
Multiple Spanning Tree (MST) Instances | 64 | |
Spanning tree protocols | STP, RSTP, MSTP | |
Maximum Aggregation Port (AP) | 128 | |
DHCP |
|
|
IPv6 protocols | IPv6 addressing, ICMPv6, Path MTU Discovery | |
IP routing |
|
|
Multicast |
|
|
ACL & QoS | ACL |
|
QoS |
|
|
Security |
|
|
Management | SNMP, CLI (Telnet/Console), RMON (1,2,4,9), Syslog, NTP, SNMP over IPv6, IPv6 MIB support for SNMP, Telnet v6, FTP/TFTP v6, DNS v6, NTP for v6, Traceroute v6
Support sFlow to sample the packets of the switch traffic using the random sampling technology of data stream |
|
Reliability | VSU (virtualization technology for virtualizing multiple devices into 1); GR for RIP/OSPF/BGP; BFD; G.8032 (ERPS), REUP; RLDP; 1+1 power redundancy; Hot-swappable power module and fan module | |
VSU (Virtual Switch Unit) | Up to 2 stack members | |
Physical Specifications | ||
Power supply |
|
|
Power Consumption | <85W | |
Power Surge Protection |
|
|
Fan |
|
|
Temperature alarm | Support temperature alarm function | |
Temperature |
|
|
Humidity |
|
|
Operating Altitude | 0 to 5,000m | |
Dimensions
(W x D x H) (mm) |
440 * 330 * 43.6(W * D * H,mm) | |
Rack Height | 1RU | |
MTBF | 30 Years | |
Safety Standards |
|
|
Emission Standards |
|